Majestic Appliances GPFMN Outdoor Fireplace User Manual


 
9
Vermont Castings GPF
Upon completing the gas line connection, a small
amount of air will be in the lines. When first lighting the
burner, it will take a few minutes for the lines to purge
themselves of this air. Once the purging is complete,
the burner will light and operate as indicated in the
instruction manual. Subsequent lighting of the
appliance will not require such purging.
Operation
WARNING: Read and follow the Safety and Lighting
Instructions page in this manual and on labels on the
appliance. IF YOU DO NOT FOLLOW THESE
INSTRUCTIONS PRECISELY, A FIRE OR EXPLOSION
MAY RESULT AND YOU MAY BE SERIOUSLY
INJURED!
FOR YOUR SAFETY READ BEFORE LIGHTING
If you cannot reach your gas supplier, call the
Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call
a qualified service technician. Applying force or
any attempted repair may result in a fire or
explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the gas control which has been under
water.
A. This outdoor cooking appliance must be lit
manually. When lighting, follow these instruc-
tions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any fireplace
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
Lighting And Operating Instructions
Lighting Instructions
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
1. STOP! Read the safety information above.
2. Remove the cover.
3. Insert the “TEE” handle in the valve.
4. Place a burning match on top of burner in the middle
where ports are present. DO NOT HOLD THE
MATCH IN HAND.
For Natural Gas unit, turn the “TEE” handle
slowly counterclockwise.
For LP unit, turn valve on the LP tank
counterclockwise all the way and then turn the
“TEE” handle on the valve slowly
counterclockwise.
5. If the burner does not light before the match goes
out, immediately turn the gas valve to “OFF”.
6. Wait at least five (5) minutes to clear out any gas. If
you have unsuccessfully tried to light the burner,
wait longer. Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B” in the safety
information above. If you do not smell gas, repeat step
4.
To Turn Off Gas To Heater
1. Turn the valve to the “OFF” position at the unit for
natural gas unit. For LP unit, turn the valve to the
“OFF” position, fully clockwise at the unit, then
turn the valve on the LP tank to the “OFF” position,
clockwise .
2. Replace the cover.