Lennox Hearth E42ODGNE Outdoor Fireplace User Manual


 
4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 2
Dexen Electronic Gas Valve
Maintenance
The appliance should be thoroughly inspected
before initial use and at least annually by a
qualified service technician. However, more
frequent periodic inspections and cleanings
should be performed by the homeowner. Ho-
meowner must contact a qualified service
technician at once if any abnormal condition
is observed.
Refer to the maintenance schedule for mainte-
nance tasks, procedures, periodicity and by whom
they should be performed. Always verify proper
operation of the appliance after servicing.
IMPORTANT: TURN OFF GAS AND ANY
ELECTRICAL POWER BEFORE SERVICING
THE APPLIANCE.
Battery Replacement
The intermittent ignition system operates on 3
volts provided by two (2) "D" cell batteries. The
batteries are located in a pack installed within
the J-Box, behind the stainless ON/OFF switch
panel.
Refer to Figure 3
.
Note: All batteries loose voltage when frozen
or left for prolonged periods. It may be wise to
remove batteries during extended periods of
disuse.
Pilot Stage
Terminal
Pressure-Tap
(Inlet)
Pilot Gas
Outlet
Supply Gas
Inlet
Pressure-Tap
(Manifold)
Burner Stage
Terminal
Ground
(TP)
PILOT
OUT
VENT
LO
TH
TP
TH
TP
HI
IN
IN
Gas Outlet
To Burner
Regulator
Mounting Screw
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled by a
remotely located wall switch.
Gas Controls/Control Compartment Access
The gas controls can be found beneath the
bottom refractory. Remove the bottom refrac-
tory by lifting it up. Remove the access cover
(
refer to Figure 1
).
All Models -
To light these appliances refer to the detailed
lighting instructions found in both English and
French on
pages 14 and 15
of these instruc-
tions respectively. The appliance lighting in-
structions may also be found on the pull out
lighting instruction labels attached to the gas
control valve. See
Figure 1
for its location.
Variable Flame Height Adjustment
1. All appliances are equipped with a variable
gas control valve. Flame height for these mod-
els may be adjusted through a range between
fixed low and high settings, alternately, while
the appliance is in operation.
Adjust the flame height as desired after light-
ing the appliance by rotating the variable ad-
justment control knob located on the front of
the valve
(see Figure 2)
.
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is
due to the burn-in of internal paints and
lubricants used in the manufacturing process.
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materi-
als, etc. It is important that control compart-
ments, burners and circulating air passage-
ways of the appliance be kept clean.
4. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.
Figure 3
Battery Replacement
Switch
Cover
Weather Seal
Orient Batteries Vertically
To Fit Within Box