KitchenAid KFRU271VSS Charcoal Grill User Manual


 
11
Make Gas Connection - To a 20 lb LP Gas Fuel Tank
If converting to local LP or Natural gas, follow instructions in the
“Gas Conversions” section.
LP Gas:
IMPORTANT: A 20 lb LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose assembly
supplied with the grill must be used. Replacement gas pressure
regulator/hose assembly specific to your model, is available from
your outdoor grill dealer.
Drawer Style Tank Tray
To Install the 20 lb LP Gas Fuel Tank:
1. Open the drawer for the 20 lb LP gas fuel tank.
2. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray
3. Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
4. Screw the gas pressure regulator/hose assembly to the 20 lb
LP gas fuel tank as shown. (To disconnect, turn off the gas
supply to the 20 lb LP gas fuel tank, then unscrew the gas
pressure regulator/hose assembly from the 20 lb LP gas fuel
tank as shown.)
5. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
6. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
7. Slide the drawer with the 20 lb LP gas fuel tank back into the
cabinet.
8. The batteries are not factory installed. The 1.5-volt “D” size
alkaline batteries are located in the accessory box on the grill
grate. Install the batteries at this time following the
instructions in the “Replacing the Batteries” section.
9. Go to “Plug in Grill” in this section.
Door Style Tank Tray
To Install the 20 lb LP Gas Fuel Tank:
1. Open cabinet doors.
2. Press the locking tab on the tank tray and pull out the tray..
3. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
A. Locking screw
B. Mounting hole
C. Bottom collar
WARNING
Explosion Hazard
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11” (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A. 20 lb LP gas fuel tank
B. Gas pressure regulator/hose assembly
A. 20 lb LP gas fuel tank tray locking tab
A
B
connect
disconnect
A