KitchenAid KBGN274 Gas Grill User Manual


 
8
This installation must conform with local
codes and ordinances**. In the absence of
local codes, installations must conform with
either the National Fuel Gas Code ANSI
Z223.1, or CAN/CGA-B149.1* Natural Gas
and Propane installation code.
Natural Gas Use
If converted to
Natural Gas
Copies of the standards listed may
be obtained from:
* CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
** for local codes, contact your local
building inspector
WARNING
Explosion Hazard
Use a new AGA or CSA approved
“outdoor” gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death,
explosion, or fire.
1.Make gas connections.
A combination of pipe fittings must be
used to connect the grill to the existing
gas line.
rear of
grill
1/2" grill
gas pipe
flexible gas
connector
If local codes permit, use an outdoor
flexible stainless steel tubing gas
connector, design-certified by AGA or
CSA International, to connect the grill to
the rigid gas supply line. 5/8" diameter
line is recommended. Using a wrench to
tighten, connect the gas supply to the
grill. Use pipe joint compound on all non-
flared male threads. Do not kink or
damage the flexible connector when
moving the grill.
• Pipe-joint compounds suitable for use
with L.P. gas must be used. Do not use
Teflon
®
tape.
valve open
2.Open shutoff valve in the gas
supply line. The valve is open when the
handle is parallel to the gas pipe.
Test all connections by brushing on an
approved non-corrosive leak-detection
solution. Bubbles will show a leak. Correct
any leak found.
valve closed
®Teflon is a registered trademark of E.I. Du Pont
de Nemours and Company.