Jenn-Air 720-0100-NG Gas Grill User Manual


 
GAS HOOK-UP
Only the pressure regulator and hose assembly
supplied with the grill should be used. Any
replacement pressure regulator and hose assembly
must be specified by the grill manufacturer.
Total gas consumption (per hour) of the 720-0100-
NG grill with all burners set on “HI”:
Main burners 48,000 BTU/Hr.
Rear burners 10,000 BTU/Hr.
Side burner 12,000 BTU/Hr.
Total 70,000 BTU/Hr.
LEAK TESTING
GENERAL
Although gas connections on the grill are leak
tested prior to shipment, a complete gas tightness
check must be performed at the installation site.
Periodically check the whole system for leaks
following the procedures listed below.
If the smell of gas is detected at anytime, you
should immediately check the entire system for
leaks.
BEFORE TESTING
Make sure all packing materials have been
removed from the grill, including the burner tie-
down straps.
WARNING
Check all gas supply fittings for leaks before each
use. Do not use the grill until all connections have
been checked and do not leak.
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent
and one part water. You will need a spray bottle,
brush, or rag to apply the solution to the fittings.
TO TEST
1. Make sure the control valves are in the “OFF”
position, and turn on the gas supply.
2. Check all connections from the natural gas
regulator and supply valve up to and including
the connection to the manifold pipe assema964TEMC