Jenn-Air 720-0061-LP Gas Grill User Manual


 
GAS HOOK-UP
Only the pressure regulator and hose assembly
supplied with the grill should be used. Any
replacement pressure regulator and hose assembly
must be specified by the grill manufacturer.
This is a liquid propane configured grill.
Do not attempt to use a natural gas supply unless
the grill has been pre-configured for natural gas
use.
Total gas consumption (per hour) of 720-0061-LP
grill with all burners on “HI”:
Main burners 45,000 Btu/hr.
Rear burners 7,000 Btu/hr
Side burner 12,000 Btu/hr.
Total 64,000 Btu/hr.
The installation of this appliance must conform with
local codes or, in the absence of local codes, with
the national fuel gas code, ANSI Z223. 1.
Installation in Canada must be in accordance with
the Standard CAN/CGA-B149.2 (installation code
for gas burning appliances and equipment) and
local codes.
LP Gas Cylinder Requirements (20lb Cylinder)
A dented or rusty LP Gas Cylinder may be
hazardous and should be checked by your LP
supplier. Never use a cylinder with a damaged
valve. The LP gas cylinder must be constructed and
marked in accordance with the specifications for LP
gas cylinders of the U.S. Department of
Transportation (DOT), or the National Standard of
Canada, CAN/CSA-B339, Cylinders, Spheres and
Tubes for Transportation of Dangerous Goods; and
Commission.
The 20lb cylinder must be provided with a shut off
valve terminating in an LP gas supply cylinder valve
outlet specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder
valve outlet and inlet connection ANSI/CGA-V-1.
The cylinder supply system must be arranged for
vapor withdrawal. The cylinder must include a collar
to protect the cylinder valve.
Manifold pressure: (operating): 10” water column
(W.C.), (non-operating): 11.2” water column (W.C.).
LP Gas Cylinder must be fitted with Overfill
Protection Device (OPD).
LP GAS HOOK-UP:
Ensure that the black plastic grommets on the LP
cylinder valve are in place and that the hose does
not come into contact with the grease tray or the
grill head.
CONNECTION:
Your grill is equipped with gas supply orifices for
use only with liquid propane gas. It is also equipped
with a high capacity hose/regulator assembly for
connection to a standard 20lb. LP cylinder (18-1/4”
high, 12-1/4” diameter).
To connect the L.P. gas supply cylinder:
1. Make sure tank valve is in its full off position
(turn clockwise to stop).
2. Check tank valve to ensure it has proper
external male threads (type 1 connection per
ANSIZ21.81).
3. Make sure all burner valves are in the off
position.
4. Inspect valve connections, port and regulator
assembly. Look for any damage or debris.
Remove any debris. Inspect hose for damage.
Never attempt to use damaged or obstructed
equipment. See your local LP gas dealer for
repair.
5. When connecting regulator assembly to the
valve, hand tighten the nut clockwise to a
complete stop. Do not use a wrench to tighten.
Use of a wrench may damage the quick
coupling nut and result in a hazardous
condition.
6. Open the tank valve fully (counterclockwise).
Use a soapy water solution to check all
connections for leaks before attempting to light
the grill. See below. If a leak is found, turn the
tank valve off and do not use the grill until a
local LP gas dealer can make repairs.
To disconnect LP gas cylinder:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise to
stop).
3. Detach the regulator assembly from the tank
valve by turning the quick coupling nut
counterclockwise.
11