GE Monogram ZGG48N42CSS Gas Grill User Manual


 
Specification Revised 9/00
Monogram.
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile
or GE appliance questions, call
GE Answer Center
®
service, 800.626.2000.
ZGG48N42CSS - GE Monogram 48" Outdoor Cooking Center
Dimensions and Specifications (in inches)
Installation in a non-combustible enclosure.
In a non-combustible (masonry) enclosure, the grill drops into the
opening and hangs from its side flanges. A deck is not required
for support.
3" Min. for Lid
Clearance
45-3/4"
18-1/2"
22-3/4"
9-1/8"
24-1/8"
18-1/4"
4x4 Opening
for Gas Supply
Line
Opening
for Access
Doors
If Installing
an Electrical
Outlet for
the Rotisserie
Motor, Mount
on Right Side
(6.5 AMP Min.)
35-1/2"
3" Min. for Lid
Clearance
51-3/4"
18-1/2"
3-1/8"
23-3/4"
10-1/8"
24-1/8"
18-1/4"
4x4 Opening
for Gas Supply
Line
Opening
for Access
Doors
If Installing
an Electrical
Outlet for
the Rotisserie
Motor, Mount
on Right Side
(6.5 AMP Min.)
35-1/2"
Installation in a combustible enclosure.
ZX48JYSS insulated jacket is required.
Combustible enclosures require insulated jackets.
ZX36JYSS for 36 models and ZX48JYSS for 48 models. The
insulated jacket must be supported from the bottom by a solid
deck or ledge on each side beneath the jacket.
Construct the enclosure as shown and place the insulated jacket
into the enclosure. Place the cooking center into the jacket. No
installation hardware is required.
Clearances - All Models
Allow 3 at the rear for lid clearance.
Allow at least 12 clearance at the back of the grill when
exhaust is directed to a window or a surface that is
difficult to clean.
Allow at least 6 clearance on each side to any non-combustible
material located above the cooking surface for counterspace.
Rotisserie models also require 6 clearance for placing and
handling the motor and skewer.
Allow at least 12 clearance on each side to combustible
vertical materials.
R
Listed by
Underwriters
Laboratories