GE Monogram ZGG36L21CSS Gas Grill User Manual


 
Specification Revised 7/02
ZGG36L21CSS GE Monogram 36" Outdoor Cooking Center
Dimensions and Specifications (in inches)
Installation in a non-combustible enclosure
In a non-combustible (masonry) enclosure, the grill drops into the
opening. A deck or ledge on each side is required for support
from the bottom.
Installation in a combustible enclosure
ZX36JYSS insulated jacket is required.
The insulated jacket must be supported from the bottom by a solid
deck or ledge on each side beneath the jacket.
Construct the enclosure as shown and place the insulated jacket
into the enclosure. Place the cooking center into the jacket. No
installation hardware is required.
Clearances All Models
Allow 3 at the rear for lid clearance.
Allow at least 12 clearance at the back of the grill when exhaust
is directed to a window or a surface that is difficult to clean.
Allow at least 6 clearance on each side to any non-combustible
material located above the cooking surface for counterspace.
Rotisserie models also require 6 clearance for placing and
handling the motor and skewer.
Allow at least 12 clearance on each side to combustible
vertical materials.
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,
®
GE Profile Performance Series
,
GE Profile
or GE appliance questions, call
GE Answer Center
®
service, 800.626.2000.
3" Min. for Lid
Clearance
34-1/2"
18-1/2"
22-3/4"
9-1/8"
24-1/8"
18-1/4"
4x4 Opening
for Gas Supply
Line
Opening
for Access
Doors
If Installing
an Electrical
Outlet for
the Rotisserie
Motor, Mount
on Right Side
(6.5 AMP Min.)
35-1/2"
3" Min. for Lid
Clearance
40-1/2"
18-1/2"
3-1/8"
23-3/4"
10-1/8"
24-1/8"
18-1/4"
4x4 Opening
for Gas Supply
Line
Opening
for Access
Doors
(6.5 AMP Min.)
35-1/2"