Garland XG24CE* Gas Grill User Manual


 
Garland Commercial Ranges Ltd.
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
General Inquires 1-905-624-0260
USA Sales, Parts and Service 1-800-424-2411
Canadian Sales 1-888-442-7526
Canada or USA Parts/Service 1-800-427-6668
Master Series Gas Xpress Grill
Form# XG24 (07/26/11)
25-1/2"
[646mm]
AVERAGE
23"
[584mm]
MAX
44.03°
AVERAGE
[48° MAX]
33-25/32"
[858mm]
24-1/8"
[614mm]
11-1/2"
[292mm]
TOP
HEATER
(2 PLACES)
TOP VIEW
24"
[610mm]
GRILL
PLATE
DEPTH
40-1/4"
[1022mm]
24"
[610mm]
GRILL PLATE WIDTH
3/4"
NPT
GAS
INLET
28-3/16"
[716mm]
FRONT VIEW
11-1/4"
[286mm]
RIGHT SIDE VIEW
7" [178mm] MIN
11" [279mm] MAX
26-23/32"
[678mm]
FROM PLATEN
ARM PIVOT
50-1/2"
[1282mm]
AVERAGE
4-41/64"
[118mm]
1-23/32"
[44mm]
2-3/4"
[70mm]
25-7/8"
[656mm]
38-25/64"
[975mm]
Model
Total
kW
Load
Loading kW/
Phase
Nominal Amps Per Line
208/220/240V 3ph
208V 220V 240V
1-Ph 3-Phase Delta 1-Ph 3-Phase Delta 1-Ph 3-Phase Delta
X-Y X-Z Y-Z L1-L2 X Y Z L1-L2 X Y Z L1-L2 X Y Z
XG24 8.66 2.66 3.33 2.66 41.63
24.90
22.14
24.90
39.36
23.50
20.94
23.50
36.08
21.61 19.19 21.61
XG24-1
L/R
4.33 1.33 1.65 1.33
20.82
12.14 11.07 12.14
19.68
11.75
10.47
11.75
18.04
10.80
9.59
10.80
XG24-F 0.66 0.66 3.17 2.74 2.74 3.00 2.59 2.59 2.75 2.38 2.38
Model
Total
kW
Load
Loading kW Per Phase Nominal Amps Per Line
380/400/415V 380V 400V 415V
L1/N L1/L2 L1/L3 L2/L3 L1/N L1 L2 L3 L1/N L1 L2 L3 L1/N L1 L2 L3
XG24CE 8.74 0.74 2.66 2.66 2.66 3.36 15.90 12.46 12.46 3.22 13.40 11.55 11.55 3.08 12.10 11.11 11.11
XG24CE-1
L/R
4.56 0.56 1.33 1.33 1.33 2.54 7.33 6.02 6.02 4.30 19.80 17.32 17.32 4.12 18.75 16.70 16.70
XG24CE-F 0.38 0.38 0.00 0.00 0.00 1.72 1.00 0.00 0.00 1.58 0.95 0.00 0.00 0.91 12.10 11.11 11.11
Clearances Gas Pressure
Total Input
Entry Installation Supply (min.) Operating
Crated Uncrated Sides Rear NAT PRO NAT PRO BTU/Hr kW
47-1/2"
(1207mm)
32"
(813mm)
6"
(152mm)
3"
(76mm)
7.0" WC 11.0" WC 3.5" WC 3.5" WC 66,000 19.4