Emerson 36J55 Outdoor Fireplace User Manual


 
2
PRECAUTIONS
SPECIFICATIONS
1. Failuretoturnoelectricormaingas
supply to heating system could cause
personal injury and/or property damage
byshock,gassuocation,re,and/or
explosion.
2. Do not use this control on circuits
exceedingspeciedvoltage.Higher
voltage will damage the control and may
causeshockorrehazard.
3. NEVER USE FLAME OR ANY KIND OF
SPARK TO CHECK FOR GAS LEAKS–
COULD CAUSE FIRE AND/OR EXPLOSION.
4. Do not use a control set for natural gas
with LP gas, or a control set for LP gas
with natural gas. Personal injury and/or
Ifyoudonotfollowtheseinstructionsexactly,areorexplosion
may result, causing property damage, personal injury or loss of life.
propertydamage,gassuocation,re,
and/or explosion may result.
5. Do not use a gas valve which appears to be
damaged. A damaged valve may cause
personal injury and/or property damage
duetoshock,gassuocation,reand/or
explosion. Contact supplier to replace any
valve that appears to have been damaged.
6. Do not use a gas valve that has been in
direct contact with water. Water entering
gas valve may result in concealed internal
damage to gas valve. Personal injury and/
orpropertydamage,gassuocation,re
and/or explosion may result.
WARNING
!
DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING
PRECAUTIONS.
WARNING
!
Properly install gas piping to control.
• Donotremoveprotectiveinletoroutletcapsuntilreadytoconnectsupplypipetogasvalve.
• Usenewsupplypipe,properlythreaded,reamed,de-burred,andcleaned.
• Usebackupwrench,appliedonlytoprovidedwrenchatsoninletboss,whentighteningthe
supply pipe. Do not grip bracket, solenoid or any other part of control.
• Donotover-tightenpipetocontrol(50ft-lbs max.)
• Alwaysinstallsedimenttrapinthegassupplylinetopreventcontaminationofgasvalve.
Failuretoinstallproperlycancausegasleakageresultingininjuryduetoreorexplosion.
CAUTION
!
1. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring
can cause equipment damage, property damage, and/or personal injury.
2. This control is not intended for use in locations where it may come in direct contact with water.
Suitable protection must be provided to shield the control from exposure to water (dripping,
spraying, rain, etc.).
3. Cleangaspipingofcontaminants,cuttinguid,orotherchemicalswhichmightreactharm-
fully with the gas valve components before install.
Parts and Accessories:
Natural to Regulated LP Gas Conversion Kits
F92-0659 for Single Stage
F92-1008 for Two-Stage
Natural to Unregulated LP Gas Conversion Kit
F92-0737
LP to Natural Gas Conversion Kits
F92-0656 for Single Stage
F92-1011 for Two-Stage
Note: Two single stage kits may be used for two-
stage valve