Emerson 36J55 Outdoor Fireplace User Manual


 
36J22, 36J24, 36J54 and 36J55
DSI and HSI Single and Two Stage
Combination Gas Valves
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
The 36J22/24/54/55 combination gas valves are de-
signed for direct spark ignition (DSI) and hot surface
ignition (HSI) system applications. These valves
are equipped with redundant and main solenoid
valves that control gas ow to the main burners, a
pressure regulator and a two-position on/o switch
for regulation and electrical shut-o of the solenoid
valves. The 36J24 and 36J55 are also equipped
with a slow-opening pressure regulator for softer
lighting characteristics. When the second solenoid
on 2-stage valves is energized the valve operates
at the second stage (high) outlet pressure setting.
Type of Gas: Natural gas
LP gas (use conversion kit)
Ambient Temperature: -40° to 175°F
Pressure Rating: 14" W.C. (½ PSI) max.
Voltage: 24 VAC
Frequency: 50/60 Hz
Current: Single Stage – 0.28A
Two-Stage – 0.43A
Mounting Positions: Multipoise – Control may
be mounted in any position
CONTENTS
Description ........................................................ 1
Specications .................................................... 1
Precautions ....................................................... 2
Installation
System Wiring ...................................... 3
Adjustment
Pressure Regulator Adjustment ............ 6
Lighting Instructions .......................................... 8
Contents French ................................................ 9
Contents Spanish ............................................ 17
36J Two-Stage
36J Single Stage
PIPE SIZES/CAPACITIES
Pipe Sizes
Available
(inches)
1
/2" x
1
/2" NPT 140,000
AGA Std. Nat. Gas
(1,000 BTU/cu. ft.)
226,800
LP Gas
(2,500 BTU/cu. ft.)
Capacity (BTU/hr) at
1” pressure drop across valve
Fig. 1
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
SPECIFICATIONS
DESCRIPTION
PART NO. 37-7338A
1224
www.white-rodgers.com
www.emersonclimate.com
Model
Number
Coil
Voltage
Stages
Opening
Characteristics
Intermittent Pilot
Proven Pilot
HSI DSI
Standing
Pilot
36J22 24V 1 Fast No Yes Yes No
36J24 24V 1 Slow No Yes Yes No
36J54 24V 2 Fast No Yes Yes No
36J55 24V 2 Slow No Yes Yes No
Pressure Regulator Adjustment Range (in W.C.)
Two Stage
Gas
Type
Single
Stage
Low High
Min. Di.
Low to High
Natural 2.5 – 5.0 1.0 – 4.0 2.0 – 5.0 1
LP 7.0 – 12.0 4.0 – 10.0 6.0 – 12.0 2