Electrolux EHG 6402 Gas Grill User Manual


 
electrolux 17
Important safety requirementsImportant safety requirements
Important safety requirementsImportant safety requirements
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation
and Use) Regulations (Current Edition) and the IEE Wiring Regulations
(Current Edition).
For appliances installed in the Republic of Ireland please refer to NSAI-
Domestic Gas Installation I.S. 813 Current Editions and the ETCI Rules for
Electrical Installations.
PrPr
PrPr
Pr
ovision for Vovision for V
ovision for Vovision for V
ovision for V
entilationentilation
entilationentilation
entilation
Detailed recommendations are contained in the following British Standards
Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current
Editions.
The hob should not be installed in a bed sitting room with a volume of less
than 20 m
3
. If it is installed in a room of volume less than 5 m
3
an air vent of
effective area of 100 cm
2
is required. If it is installed in a room of volume
between 5 m
3
and 10 m
3
an air vent of effective area of 50 cm
2
is required,
while if the volume exceeds 11 m
3
no air vent is required.
However, if the room has a door which opens directly to the outside no air
vent is required even if the volume is between 5 m
3
and 11 m
3
.
If there are other fuel burning appliances in the same room, B.S. 5440
Part 2 Current Edition, should be consulted to determine the requisite air
vent requirements.
For appliances installed in the Republic of Ireland please refer to the NSAI-
Domestic Gas Installation I.S. 813 Current Editions Table Four.