Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
www.desatech.com
116236-01G36
TROUBLESHOOTING
Continued
-
1. Gas leak.
1. Gas leak.
2. Control valve defective
1. Gas leak.
1. Air holes at burner inlet
blocked
2. Burner ame holes blocked
3. Improper venting or excessive
blockage
4. Excessive amounts of embers
and pan material
Fireplace produces unwanted
odors
Gas odor even when control knob
is in OFF position
Gas odor during combustion
Dark residue on logs or inside
of replace
REMEDY
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 23)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 23)
2. Replace control valve
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 23)
1. Clean out air holes at burner
inlets. Periodically repeat as
needed
2. Remove blockage or replace
burner
3. Have the vent system inspect-
ed, including the termination
cap. Remove any restrictions
or obstruction
4. Clear excess embers until a
minimum gap of 1/2" remains
under the grate