Desa (V)VC42N Outdoor Fireplace User Manual


 
www.desatech.com
116236-01G36
TROUBLESHOOTING
Continued

 
 
 

 -

 

1. Gas leak.  

1. Gas leak.  

2. Control valve defective
1. Gas leak.  

1. Air holes at burner inlet
blocked
2. Burner ame holes blocked
3. Improper venting or excessive
blockage
4. Excessive amounts of embers
and pan material

Fireplace produces unwanted
odors
Gas odor even when control knob
is in OFF position
Gas odor during combustion
Dark residue on logs or inside
of replace
REMEDY
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 23)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 23)
2. Replace control valve
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 23)
1. Clean out air holes at burner
inlets. Periodically repeat as
needed
2. Remove blockage or replace
burner
3. Have the vent system inspect-
ed, including the termination
cap. Remove any restrictions
or obstruction
4. Clear excess embers until a
minimum gap of 1/2" remains
under the grate