Desa VMH10TPA Outdoor Fireplace User Manual


 
19
104407
OWNER’S MANUAL
INSPECTING
BURNER
Thermocouple
Pilot Burner
Figure 31 - Correct Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure 31 shows a correct pilot flame pat-
tern. Figure 32 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the fireplace will shut
down.
If pilot flame pattern is incorrect, as shown
in Figure 32
turn fireplace off (see To Turn Off Gas to
Appliance, page 18)
see Troubleshooting, pages 20 through 22
Thermocouple
Pilot Burner
Figure 32 - Incorrect Pilot Flame Pattern
(Actual Pilot May Vary From Illustration)
BURNER FLAME PATTERN
Figure 33 shows a correct burner flame
pattern. Figure 34 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows the flame consistently higher
than one inch above the log.
If burner flame pattern is incorrect, as shown
in Figure 34
turn fireplace off (see To Turn Off Gas to
Appliance, page 18)
see Troubleshooting, pages 20 through 22
Figure 33 - Correct Burner Flame Pattern
Figure 34 - Incorrect Burner Flame Pattern
Top of Flame Consistently About
One Inch Higher Than Logs
Top of Flame About
One Inch Below Logs