Desa (V)CD36RNE Outdoor Fireplace User Manual


 
www.desatech.com
116035-01E18
VENTING INSTALLATION
INSTRUCTIONS
Continued


Figures 28 and 29 show two different congura-
tions for vertical termination.
VERTICAL VENT INSTALLATIONS USING
MULTIPLE 90° ELBOWS (V)CD36R REAR
VENT
Figure 28 - Vertical Venting
Conguration using One 90° Elbow
(Model (V)CD36R with Vertical Round
High Wind Termination)
Figure 29 - Vertical Venting
Conguration using Three 90° Elbows
(Model (V)CD36R with Vertical Round
High Wind Termination)



1
Horizontal
(H
1

1


2

Horizontal (H
2
8' Min. 2' Max. 12' Min. 8' Max
8' Min. 2' Max. 14' Min. 11' Max
8' Min. 2' Max. 16' Min. 14' Max
8' Min. 2' Max. 18' Min. 17' Max
8' Min. 2' Max. 20' Min. 20' Max
8' Min. 2' Max. 40' Min. 20' Max
Note: Vertical (V
1
) + Vertical (V
2
) = 40' Max.
Max. Horizontal Above 20' Vertical = 20'

 
8' Min. 2' Max
40' Min. 2' Max
90°
Elbow
90°
Elbow
90°
Elbow
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.
Note: Install a
VR-58 vertical
restrictor ring
into inner pipe
section prior to
attaching vent
termination
cap.