www.desatech.com 111604-01E
28
SPECIFICATIONS
LMFP33NR LMFP33PR
Btu (Variable) 23,000/33,000 23,000/33,000
Type Gas Natural Gas Only Propane/LP Only
Ignition Piezo Piezo
Pressure Manifold 3.5" W.C. 7.9" W.C.
Inlet Gas Pressure (in. of water)
Maximum 10.5" 14"
Minimum* 5.5" 11"
Shipping Weight 122 lbs. 122 lbs.
* For input adjustment
WIRING DIAGRAM
Black
Red
White
Red
TECHNICAL SERVICE
You may have further questions about installation,
operation, or troubleshooting. If so, contact DESA
Heating Products’ Technical Service Department
at 1-866-672-6040. When calling, please have your
model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ tech-
nical services web site at www.desatech.com.
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burner will have delayed ignition
fireplace will not produce specified heat
for propane/LP unit, propane/LP gas supply
may be low
You may feel your gas pressure is too low. If so,
contact your local gas supplier.
REPLACEMENT PARTS
Note:
Use only original replacement parts. This
will protect your warranty coverage for parts re-
placed under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), call
DESA Heating Products’ Technical Service De-
partment at 1-866-672-6040. When calling DESA
Heating Products, have ready
your name and address
model and serial numbers of your fireplace
how fireplace was malfunctioning
type of gas used (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the part to the
factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they
can’t supply original replacement part(s), call
DESA Heating Products at 1-866-672-6040 for
referral information. When calling DESA Heat-
ing Products, have ready
model number of your fireplace