Desa KC42N Outdoor Fireplace User Manual


 
www.desatech.com
116239-01F6
When locating termination cap, it is important
to observe the minimum clearances shown in
Figure 7, page 8.
If recessing into a wall, you can avoid extra
framing by positioning your replace against
an already existing framing member.
Do not recess termination cap into a wall or
siding.
You may paint the termination cap with 450º F
(232º C) heat-resistant paint to coordinate with
the exterior nish.
There must not be any obstruction such as
bushes, garden sheds, fences, decks or util-
ity buildings within 24" from the front of the
termination cap.
Do not locate termination cap where excessive
snow or ice build up may occur. Be sure to
clear vent termination area after snow falls to
prevent accidental blockage of venting system.
When using snow blowers, do not direct snow
towards vent termination area.
For horizontal installations above 2,000 feet, it
is recommended that a 12" extension pipe be
added before starter elbow and a round hori-
zontal termination be used (see High Altitude
Installation, page 17).
CLEARANCES
Minimum clearances to combustibles for the re-
place are as follows:
*Back and sides 0"
Perpendicular walls 6"
Floor 0"
Ceiling to louver opening 42"
Front 36"
Top of Standoffs 0"
Vent ( Se e ve nt in g
instructions for
specific venting
clearances.)
Combustible material with a maximum thick-
ness of 5/8" may be ush with the top front of
replace.
* For back and sides of replace, do not pack
with insulation or other materials. Zero inch
clearance to combustible materials are for fram-
ing purpose only.
PRE-INSTALLATION
PREPARATION
Continued
    -

    
-

    
     

   





FRAMING AND FINISHING
Figure 4 shows typical framing of this replace.
Figure 5 shows framing for corner installation. All
minimum clearances must be met.
For available accessories for this replace, see
Accessories on page 42. If you are using a sepa-
rate combustible mantel piece, refer to Figure 6
for proper installation height. You can install
noncombustible mantels at any height above the
replace.
Note: Noncombustible mantels may discolor!
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
40
1
/8"
48
1
/4"
23" Horizontal Vent
26
1
/2" Vertical Vent