112301-01D 7
FIREPLACE
INSTALLATION
Continued
FRAMING
Construct framing using dimensions shown if
Figures 6, 7 and 8. (Use the gure applicable to
your application.) Figure 6 shows the framing
dimensions prior to having the appliance in place.
If installing on a platform, platform must be solid,
at and fully supported (see Figure 7). Once the unit
has been tted, bring studs in against nailing anges
located on the side of the appliance making sure
a 1" clearance is maintained as shown in Figure 8.
If the replace is to be installed directly on carpeting,
tile (other than ceramic) or any combustible mate-
rial other than wood ooring the replace must be
installed upon a metal or wood panel extending the
full width and depth of the replace.
Figure 6 - Framing Dimensions Prior to
Placing Appliance
Figure 8 - Securing Appliance with
Nailing Flanges
52
3
/
4
"
Min.
41"
25
5
/
8
"
VENT PIPE INSTALLATION
A 6" B-1 type gas vent pipe is a double wall, vent-
ing system (not supplied) which must be installed
during rough framing of the appliance. Any B-1
type gas vent system may be used for proper vent-
ing as long as the vent system is installed per the
vent manufacturer’s recommendations.
DESA supplies this appliance with a tapered starter
pipe for a snug t. Slide B-1 type vent pipe over
this starter pipe until vent pipe is fully seated.
Secure this rst section of B-vent pipe by strap-
ping the connector around the vent pipe and then
tightening the strap with any 1/8" nut and bolt (see
Figure 9). Note: Visually inspect for proper vent
connection by looking inside top of appliance. If
connection does not appear to be correct, contact
your local service technician.
Figure 9 - Installing B-Vent Pipe
Nailing
Flange
1" Min. to
Combustibles
Prepared
Framing
Nails or
Screws
B-1 Type
Vent (Not
Supplied)
Strap
(Fasten with
1/8" Screw
or Bolt)
52
3
/
4
"
Min.
24"
*
Figure 7 - Framing Dimensions Prior to
Placing Appliance Using a Platform
*As required by design as
long as ceiling clearance is
maintained