Vermont Casting VCS501 Gas Grill User Manual


 
14
30005436
VCS501 Series Assembly
CAUTION: Some parts may have sharp edges; to avoid injury, wearing gloves during assembly, lifting or
moving the grill is recommended.
Step 13: Install the LP Cylinder
(LP Models ONLY)
Parts Required:
(1) LP Gas Cylinder (not included)
Figures 16 & 17
NOTE: Check your User’s Manual for the cylinder lling requirements, how to attach the regula-
tor and how to test for leaks before you try lighting the grill.
CAUTION: Make sure the hose is not touching any hot or sharp surfaces.
Place the LP Cylinder into the hole in the bottom panel. Next secure it from moving by lifting the
cylinder retainer wire and latching the bent edge over the lip of the cylinder.
The nal step is to connect the regulator to the cylinder.
CAUTION: Do not turn on/ignite the grill until after performing a leak check at all gas connection
points and ttings. With the main LP cylinder valve OPEN, and ALL CONTROL KNOBS FULLY
OFF, use a spray solution of 50% liquid soap and 50% water onto all gas connection points and
ttings. The formation of bubbles indicates an air leak that must be repaired and veried with
this leak test before the grill is ignited.
NOTE: Ensure all plastic coatings have been removed from all stainless steel parts before using
the grill.
Figure 16
B358
install tank
11/10
B358
B359
tank in place
11/10
Figure 17
B359