Vermont Casting 3405BGW Smoker User Manual


 
21
Lighting Procedure
Igniter Lighting System:
Match Lighting:
1. Check all connections for leaks using the “soapy water”
test as explained on page 16.
2. Open the smoker cabinet door.
3. Check for any blockage to the venturi tube or burner.
Remove any foreign objects or matter.
4. Be sure the burner control knob is in the “OFF” position.
5. Open the LP cylinder valve by turning
counter-clockwise.
6. To light unit with the igniter, push in and turn the burner
control knob counter-clockwise to the high setting.
7. Immediately press or rotate the igniter repeatedly to
click it several times (you should see a small spark
jumping from the end of the electrode rod to the side of the
burner). If the burner doesn’t light within 3 to 5 seconds,
turn the burner control knob off and wait five minutes
before repeating the steps again. If burner still fails to light
try match lighting the smoker using the instructions noted
below.
8. Once the burner is lit, then close the door to allow heat
to accumulate. The dampers can then be adjusted to the
desired setting to allow proper air flow and combustion.
Damper adjustment tips are listed on the next page.
1. Repeat steps 1 thru 5 of the Igniter Lighting System
above.
2. Remove the Wood Chip Box and its stand from inside
the smoker. Light a paper match and drop it into the burn
chamber, making sure it falls next to the brass burner.
Quickly turn the control knob to the light position. If the
burner does not light within 4 or 5 seconds, turn the control
knob off, wait 5 minutes, and repeat the process.
1-1/2 turn