Broilmaster BBA-1 Gas Grill User Manual


 
Page 14 B101502-3-1012
Lower the BBA Door Assembly onto the two hinge pins
inside the lower left and right sides of the BBA Frame.
FIGURE 4 .
ENCLOSURE REQUIREMENTS
The enclosure design must be constructed to allow
only storage of the LP cylinder in use thus preventing
storage of a second cylinder. Tank caddy must be
provided for use in the enclosure when employing the
propane self-contained system so as to prevent the
lateral movement of the propane tank cylinder from its
enclosure.
An enclosure for a LP gas cylinder shall be ventilated
by openings at the level of the cylinder valve and at oor
level. The effectiveness of openings(s) for purposes of
ventilation shall be determined with the LP gas supply
cylinder in place. This shall be accompanied by one
of the following: enclosure with one side completely
open; or enclosure having four sides, a top and a
bottom. Refer to the Built-In Kit enclosure construction
guide for proper dimensions of the opening for the
BBA-1 Tank Caddy.
1. At least two ventilation openings at cylinder valve
level shall be provided in the side wall, equally
sized, spaced at 180 degrees (3.14 rad), and
unobstructed. Each opening shall have a total free
area of not less than 1/2 square inch per pound
(7.1 cm
2
/kg) of stored fuel capacity and not
less than a total free area of 10 square inches
(64.5 cm
2
).
2. Ventilation opening(s) shall be provided at oor
level and shall have a total free area of not less
than 1/2 square inch per pound (7.1 cm
2
/kg) of
stored fuel capacity and not less than a total free
area of 10 square inches (64.5 cm
2
). If ventilation
openings at oor level are in a side wall, there
shall be at least two openings. The bottom of the
openings shall be at oor level and the upper edge
no more than 5 inches (127 mm) above the oor.
The openings shall be equally sized, spaced at
180 degrees (3.14 rad) and unobstructed.
3. Every opening shall have minimum dimensions so
as to permit the entrance of an 1/8 inch (3.2 mm)
diameter rod.
The cylinder valve shall be readily accessible for hand
operation. A door on the enclosure to gain access to
the cylinder valves is acceptable, provided it is non-
locking and can be opened without the use of tools.
The enclosure for the LP gas cylinder shall isolate
the cylinder from the burner compartment to provide
shielding from radiant heat, a ame barrier, and
protection from foreign material, such as hot drippings.
There shall be a minimum clearance of 2 inches
(50.8 mm) between the oor of the LP gas cylinder
enclosure and the ground.
The design of the outdoor cooking gas appliance shall
be such that the LP gas cylinder can be connected,
disconnected and the connections inspected and
tested outside the cylinder enclosure; and those
connections which could be disturbed when installing
the cylinder in the enclosure can be leak tested inside
the enclosure.
BBA TANK CADDY INSTALLATION
4
FIGURE 4
HINGE
PIN