Aiphone AC-10S Turkey Fryer User Manual


 
5
English
Nederlands
FrançaisDeutschEspañol
FUNCTIONS SETTING UP
This section explains the settings of each function, including the master code for management, the user code for unlocking, the
buzzer and the LEDs.
About the setting mode:
Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings
for the desired function. After settings have been made, enter the following setting codes to continue the setting
operation. Press
to exit the setting mode.
Setting items Allowable setting range Default value
Setting code
Setting the code length
Change the length of the master code and the user code.
)They both must be the same length.
4, 5, or 6 digits 4 digits
Setting the master code
Enter a master code using between 4 and 6 digits (alpha or numeric) to
switch to the setting mode.
) The number of digits in the code can be set by setting the code length.
1
Valid keys: 0 - 9, A, B
1234
Setting the code for user group 1
Set the unlocking code for user group 1.
) The number of digits in the code can be set by setting the code length.
Number of codes: 60
Valid keys: 0 - 9, A, B
-
-
Setting the code for user group 2
Set the unlocking code for user group 2.
) The number of digits in the code can be set by setting the code length.
Number of codes: 40
Valid keys: 0 - 9, A, B
-
-
Setting the key illumination time
Set the length of time that the keys will be lit up after they are pressed.
Illumination time: 10 to 99
seconds, or continually lit
10 Sec.
Setting the relay 1 output time
Set the output time of relay 1.
Output time: 1 to 99
seconds, or latched
3 Sec.
Setting the relay 2 output time
Set the output time of relay 2.
Output time: 1 to 99
seconds, or latched
3 Sec.
Reset Settings
Return all the settings to their default values.
--
External output setting
The alarm or security system connected to the terminal of relay 2 will be
activated when the "Lockout" * or the forced entry* is carried out.
* "Lockout": Refer to VIII below. *Forced entry: This function is linked with
the door open/close sensor (N.C.) which is connected to PB2 and C, and
carried out when opening the door without activating this unit. (For example,
entry in an improper manner, manual unlock, etc.)
) If there is a way to open the door without activating this unit, such as
manual unlock, do not make the external output setting for the forced entry.
· OFF
· During Lockout
· During forced entry output
·
During lockout and forced
entry output
OFF
Lockout
If several incorrect access codes are attempted, the code input function is
disabled for a programmed period of time.
· When "Lockout" is activated, the LED (Orange) indicator and the keypad
blink, and the buzzer sounds for 3 seconds. This is just a sound to inform
you that the function has been activated. It is not a warning sound. If you
want a warning to be sounded, please use the external output function to
activate a commercially-available alarm device.
· The unlock function will work when the request to exit/entry button is
pushed, even while the "Lockout" function is operating.
ON/OFF
Invalid number of times:
10 to 99 times
Invalid time:
10 to 99 seconds
OFF
Auto-relock (Anti-tailgate)
After the door has been linked to the door open/close sensor (N/C), and
unlocked, it will relock itself one second after being closed, thus preventing
the entry of an unauthorized third party.
)1
ON/OFF OFF
Timer-linked unlocking setting
The system can be set to unlock the door by pressing the key within
the set time and linking it to the external timer (N/O). The operations for the
LEDs and the buzzer after unlocking are the same as those used to perform
user code unlocking. When the door is linked to the timer, unlocking can be
performed using the user code and the request to exit/entry button. When
latch output is performed for the relay settings, the relay turns ON/OFF
every time the
key is pressed.
Linked relay: relay 1
relay 2
relay 1 and 2
0 key illumination: ON/OFF
Linked relay: relay 1
0 key illumination: OFF
Operation tone settings
Set the tone heard when the keypad is being used to ON/OFF.
ON/OFF ON
The setting can be saved even when the power is off.
The system cannot be switched to the setting mode while the relay is unlocked.
When the setting mode has been activated and no operations are performed for approximately 120 seconds, the system
will exit the setting mode. (If a key is pressed during that time, the timer will start over.)
Neither the request to exit/entry button nor the timer-linked unlocking
key can be operated, and unlocking using the
user code cannot be performed while the setting mode is activated.
The volume (the check tone, operation tone, etc.) from the main unit may become lower according to the mounting status.
1
: When the auto-relock is used, the request to exit/entry button for relay 2 cannot be used. The output of relay 2 is
only possible when user code unlocking is performed.