Emerson MON2020 Gas Grill User Manual


 
You have two options: User_Modbus, which is a PLC emulation Modbus protocol
that can use scaling to convert floating point numbers to integers; and SIM_2251,
which emulates the Daniel 2500 communication protocol and is a simulation of the
2251 GC controller.
Note
The table’s column headers change based on which protocol is selected.
5. If you want to base the MAP file on an existing MAP file, do the following:
a. Click Import.
The Open window displays.
b. Select the file that you want to import and click Open.
The registers from the selected file will load into the table.
6. To edit a cell, double-click it.
You can edit the following parameters:
Register
Number
Displays the number for the Modbus registers that will be polled by
a connected data acquisition system.
Data Type Describes the type of data that is stored in the register.
Options are:
BOOLEAN. Has two states ON (1) or OFF (0).
INT. 16-bit unsigned integer.
LONG. 32-bit signed integer
Note
If the Modbus data type is Usr Modbus, each long value uses two
registers; if the data type is SIM2251, each long value uses a single
register.
ULONG. 32-bit unsigned integer
FLOAT. 32-bit floating point.
Note
If the Modbus data type is Usr Modbus, each floating point value uses
two registers; if the data type is SIM2251, each floating point value
uses a single register.
Bitmap(INT)
Bitmap(LONG)
SCALED_FP1
...
Application